Linear Actuator Installation Guide

Installation Guide

1.Stepper Motor External Linear Actuator + Linear Guide

2.Stepper Motor Non-Captive Linear Actuator + Linear Guide


3.Stepper Motor External Linear Actuator + Guided Rod


4.Stepper Motor Non-Captive Linear Actuator + Guided Rod


5.Stepper Motor Captive/Kaptive Linear Actuator Mounted to Load Directly

** Please select one of installation guide according to your application and it is strongly recommended from DINGS' to use our linear actuator in longer life cycle and for proper usage.

Screw End Machining

opt screw end machining

Stepping Sequence

stepping sequence images
Bipolar Q2-Q3 Q1-Q4 Q6-Q7 Q5-Q8
Unipolar Q1 Q2 Q3 Q4
Step
1 ON Off ON Off
2 Off ON ON Off
3 Off ON Off ON
4 ON Off Off ON
5 ON Off ON Off

Typical Electrical Connection

typical electrical connection image

Operation Guides

  • Do not dismantle the motor in any case.
  • Do not apply radial force to the screw. Do not lift, hang, push or pull the screw during usage or transport.
  • Do not add any lubrication to the nut and screw. Protect the grease from being wiped off and no other grease shall be used except those from DINGS'.
  • Measures should be taken to protect the leadscrew surface from dust.
  • Do not drop the motor or screw during usage.
  • Do not apply force or tension to the lead wire.
  • When using a chopper driver, please set the current (RMS) to the rated current of the motor. Overdriving is not recommended, as it could overheat the motor and cause the coils to melt/burn without initial testing.
  • Operate in ambient temperatures between -22°C to +55°C.
  • To get the designed lifetime, actual load should be lower than 50% of the calculated data and try to avoid the missing step or stuck. Don't drive the motor beyond its designed stroke for Captive and Kaptive structure. Impact, immediately stop or start should be avoided, too.
  • Storage conditions: Ambient temperature and pressure, relative humidity <75%, clean, noncorrosive environment.